Deprecated: Hook the_seo_framework_rel_canonical_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_description_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_ogtitle_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_ogurl_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031
Heating Stage 2000 for IX2-SP

Heating Stage 2000 for IX2-SP

This stage enables heat­ing of cell cul­ture sys­tems on the micros­cope. The object guide and other acces­sories can be attached and a great vari­ety of cul­ture ves­sels can be used.

Description:

  • The Heat­ing Stage replaces the stan­dard fixed stage and enables the heat­ing of objects on the microscope
  • The object guide and other acces­sories can be attached
  • All con­ven­tion­al­ly used cul­ti­va­tion ves­sels can be used
  • Solid design with a high ther­mal capac­i­ty and a high tem­per­a­ture stability
  • Rec­om­mend­ed for elec­tro­phys­i­o­log­i­cal exper­i­ments because no dis­turb­ing switch­ing puls­es are emitted
  • Oper­a­tion is indi­cat­ed by a green LED at the front
  • A self-resetting over-temperature switch ensures max­i­mum oper­a­tional safety

Specifications:

Material aluminium, black anodized
Operating voltage 20 V DC
Power consumption 2.2 A max.
Control range 3°C above room temperature up to 60°C
Temperature sensor Pt100
Control accuracy ± 0.1°C
Observation opening approx. 30 x 34 mm
Dimensions 240 x 232 x 29 mm
Weight approx. 2.4 kg
Operating temperature + 5°C up to + 40°C
Rel. humidity max. 80%, non-condensing
Heating Stage 2000 for IX2-SP

Compatibility:

  • Olympus IX2 series with an object guide

Compatible PeCon Products:

To hold and move the cell culture vessel, an object guide and an Universal Mounting Frame or Insert are required:

Application Examples:



This page is using Google Analytics. Press "X" to accept and hide this box in the future.
Click here to opt-out.