Deprecated: Hook the_seo_framework_rel_canonical_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_description_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_ogtitle_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_ogurl_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031
Heating Stage Primovert

Heating Stage Primovert

This stage with an embed­ded con­troller enables the heat­ing of cell cul­ture sys­tems on the micros­cope. The object guide and other acces­sories can be attached and a great vari­ety of cul­ture ves­sels can be used.

Description:

  • Heat­ing Stage for the invert­ed micros­cope Pri­movert by Zeiss
  • The Heat­ing Stage replaces the stan­dard fixed stage and enables the heat­ing of objects on the microscope
  • Due to an embed­ded con­troller, no addi­tion­al con­trol unit is needed
  • The object guide and other acces­sories can be attached
  • All con­ven­tion­al­ly used cul­ti­va­tion ves­sels can be used
  • Solid design with a high ther­mal capac­i­ty and a high tem­per­a­ture stability
  • Rec­om­mend­ed for elec­tro­phys­i­o­log­i­cal exper­i­ments because no dis­turb­ing switch­ing puls­es are emitted
  • Easy oper­a­tion: After the switch-on, the micros­cope stage heats up to 37°C automatically
  • Three LEDs for tem­per­a­ture control:

Specifications:

Material aluminium, black anodized
Operating voltage 20 V DC
Power consumption 2.2 A max.
Control range between 36.5°C and 37.5°C
Temperature sensor Pt100
Control accuracy ± 0.5°C
Observation area approx. 25 x 55 mm
Dimensions 239.2 x 200 x 15 mm
Weight approx. 1.5 kg
Heating Stage Primovert

Requirements:

  • none

Compatibility:

  • Zeiss Primovert with an object guide

Compatible PeCon Products:

To hold and move the cell culture vessel, an object guide and an Universal Mounting Frame or Insert are required:

Application Examples:

  • none