Deprecated: Hook the_seo_framework_rel_canonical_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_description_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_ogtitle_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031

Deprecated: Hook the_seo_framework_ogurl_output is deprecated since version 5.0.0 of The SEO Framework! Use the_seo_framework_meta_render_data instead. in /var/www/clients/client262/web1123/web/wp-includes/functions.php on line 6031
TempModule S

TempModule S

The Temp­Mod­ule S is a tem­per­a­ture con­trol unit and serves as the base for fur­ther mod­ules of the Incu­ba­tion Sys­tem S. It has 4 equal, inde­pen­dent chan­nels to elec­tri­cal­ly heat var­i­ous PeCon components.

Description:

  • Tem­per­a­ture con­trol unit with 4 equal, inde­pen­dent chan­nels to elec­tri­cal­ly heat var­i­ous PeCon components
  • The Temp­Mod­ule S is the base for fur­ther mod­ules of the incu­ba­tion sys­tem and auto­mat­i­cal­ly sup­plies them with elec­tri­cal power and com­mu­ni­ca­tion sig­nal via a sys­tem bus
  • An addi­tion­al port for an exter­nal tem­per­a­ture sen­sor allows the deter­mi­na­tion of the tem­per­a­ture inside the cell cul­ture ves­sel dur­ing pre-experiments
  • A power sup­ply pack with a wide range input allows the oper­a­tion of the Temp­Mod­ule S with all com­mon AC line volt­ages with­out man­u­al adaptation
  • The mod­ule is oper­at­ed exclu­sive­ly with an exter­nal user inter­face (PC-Software Zeiss ZEN / Axio­vi­sion (V4.6 or high­er) or TFT dis­play at the micros­cope) and has no dis­play or input panel
  • Com­mu­ni­ca­tion with the exter­nal con­trol unit can either be car­ried out via CAN (micros­cope) or via USB (PC)

 

Specifications:

AC operating voltage AC 100-240 V, 50... 60 Hz
Power consumption 460 VA max.
Mains fuse 250 V T4A(H)
Output DC 24 V; max. 4 A per channel; max. 14 A total power (incl. power consumption of additional modules)
Temperature display 0.0 up to 99.9°C Resolution 0.1°C
Loop control range (Setpoint) 0.0 up to 60.0°C
Loop control accuracy typ. ± 0.15% of setpoint value (e.g.: 37.0 ± 0.05°C) internal resolution 0.01°C
Dimensions (WxHxD) 313 x 85.5 x 301 mm
Weight approx. 5.4 kg
Operating temperature + 5°C up to + 40°C
Rel. humidity max. 80 %, non-condensing
Altitude max. 2000 m above sea level
Overvoltage category 2
Pollution degree 2
Protection class I
 
TempModule S

Requirements:

  • none

Compatibility:

  • all devices of the Zeiss Series S (and the PeCon Series 2000)